中文版English

Products

Home>SAS 22Pos

SAS 22P to SATA 7P W/Latch+Power

Part Number: RSS22-0106
(Note: The part number is only for reference. If you have requirement, please contact Amphenol for further confirming PN and drawing)
Product Description: SAS 22P to SATA 7P+Power
Series: SAS
Cable Length: 0.65 meters
Wire Size: SATA CABLE,30AWG,Tinned Copper, OD:1.7*5.7MM
UL1007, 18AWG, Tinned Copper, OD:2.1MM
Plating: Au15u” over Ni
Color: Cable Red、Black、Yellow, Over mold Black
Environmental Compliance: ROHS2.0
Flammability: Cable:VW-1, Overmold 94V-1 or Better

SAS 22P to SATA 7P W/Latch+Power

Part Number: RSS22-0106
(Note: The part number is only for reference. If you have requirement, please contact Amphenol for further confirming PN and drawing)
Product Description: SAS 22P to SATA 7P+Power
Series: SAS
Cable Length: 0.65 meters
Wire Size: SATA CABLE,30AWG,Tinned Copper, OD:1.7*5.7MM
UL1007, 18AWG, Tinned Copper, OD:2.1MM
Plating: Au15u” over Ni
Color: Cable Red、Black、Yellow, Over mold Black
Environmental Compliance: ROHS2.0
Flammability: Cable:VW-1, Overmold 94V-1 or Better

Applications

    Data/Communications

1.Independent Disks

2. CD driver

3.Workstations

4.Servers

5.Storage rack

 

Features and Benefits

1. Transmission rate 6 Gbps.

2. Meet SAS 3.0 specification.

 

Mechanical Performance

1. Mating Force and Unmating Force

Condition: EIA 364-13. Insert and extract at a speed of 25mm/minute. 

Mating Force: 50 N maximum

Unmating Force: 20 N minimum

2. Durability:

Condition: EIA 364-09. Mated and Unmated connector for 25cycles at a rate of 200 cycles per hour.

No physical damage and shall meet requirements of subsequent test.

   

Electrical Performance

1. Contact Resistance

Condition: EIA 364-23. Subject mated contacts assembled in housing to 20mV maximum. Open circuit at 100mA maximum.

30 mohm max, initial per contact mated pair.

2. Dielectric Withstanding Voltage

Condition: EIA 364-20. Method B. Test between adjacent of mated and unmated connector assemblies. The dielectric shall withstand 500 VAC for 1 minute at sea level.

No flashover, no spark over, no excess leakage and no breakdown.

3. Insulation Resistance

Condition: EIA 364-21. Met



Last:没有了!